Product image is representative only, please verify specifications.
514103
Alt: 1001A-WPSA-CI-YZ-LH-VX, Non-Cancellable, No Returns per Manufacturer
Purge System with Pressure Switch (120VAC), Class I, Left Side Mount, Vortex, Please Note Bebco Items are Non-Cancellable, Non-Returnable
- Weight:
- 10.00 LBS
- Minimum Purchase:
- 1 unit
Well known in the process automation industry, Bebco EPS® purge and pressurization by Pepperl+Fuchs are remarkably simple to use and will easily handle just about any application.
With Pepperl+Fuchs' Bebco EPS purging and pressurization, you get:
- State-of-the-art solutions based on more than 20 years of experience
- A complete family of automatic purge and pressurization systems that make hazardous location protection easy
- Purge and pressurization systems designed according to ATEX direction 94/9/EG, NFPA 496, and ISA 12.4 standards
- Easy integration – compact, low-profile designs that can be internally or externally mounted
- Automatic temperature and leakage control and alarming
- User interface with programming to meet most users' demands
We offer a full range of purge and pressurization equipment that use standard Type 4/12 enclosures as the protected enclosure. This will save you money, weight, and space over explosion-proof methods. We can also design custom, certified enclosure solutions.
The purging and pressurization types that Pepperl+Fuchs/Bebco offer include:
- Type X purge system
- Type Y purge system
- Type Z purge system
- Ex px purge system
- Ex pz purge system
- Eniro-Line pressurization system
More information on each type is below:
The Pepperl+Fuchs Bebco EPS Type X purge system reduces the classification within the protected enclosures from Division 1 to non-hazardous. General-purpose equipment can be operated within the protected enclosure. This type includes the 6000 series and 2000 series.
The Pepperl+Fuchs Bebco EPS Type Y purging system reduces the classification within the protected enclosure from Division 1 to Division 2. All equipment used within the enclosure must be Division 2 rated. This type includes the 3000 series and 1000 series.
The Pepperl+Fuchs Bebco EPS Type Z purge system reduces the classification within the protected enclosure from Division 2 to non-hazardous. General-purpose equipment can be operated within the protected enclosure. Type Z includes 5500 series, 3000 series and 1000 series.
The Pepperl+Fuchs Bebco EPS Ex px purge system reduces the classification within the protected enclosure from Zone 1/ Zone 21 to non-hazardous. General-purpose equipment can be operated within the protected enclosure. Vents are reqruied for all purge enclosures! This type includes the 6500 series and 6000 series.
Ex pz purge systems reduce the classification within the protected enclosure from Zone 2 to non-hazardous. General-purpose equipment can be operated within the protected enclosure. This type includes the 5500 seires, 5000Q series and 3000 series.
Enviro-Line purging units is an enclosure pressurization system for non hazardous areas that operates on a supply of compressed instrument air or inert gas. It regulates and monitors the pressure within the sealed enclosure in order to prevent the accumulation of damaging and caustic gases and dusts. By eliminating these gases and dusts you can extend the life of your electrical equipment that are within the Enviro-Line purging unit. The systems maintains a constant 0.5" water pressure inside the enclosure.
Marshall Wolf Automation is your authorized Pepperl+Fuchs distributor. We offer in-house tech support and can work with Bebco/Pepperl+Fuchs to help you with your application.
Features Include:
- NFPA 70, NFPA 496, ISA 12.4 standards
- Optional alarm output indicates air lock failure
- Type Y system certified for Class I and Class II, Division 1 to Division 2
- Type Z system certified for Class I and Class II, Division 2 to nonhazardous area
- Class I enclosure volume up to 2 ft3
- Class II enclosure volume up to 10 ft3