Weg
SSW900D0412T5E3B
Soft Starter, 3 Phase, 412 Amp, 230/460/575VAC, 150/350/450hp, Frame D: 13.0H x 8.9W x 11.1D”, Protected Chassis Enclosure, IP00. (Please review and verify specifications for your application.)
$5,868.30$5,868.30 -
Weg
GPH2075QC2001
Soft Starter, 75hp, 200A, 3 Phase, 200-240VAC, NEMA 4/12 Enclosure with Circuit Breaker, AC1 Bypass & Keypad on Door
$5,545.90$5,545.90 -
Weg
GPH2020PC4001
Soft Starter, 20hp, 30A, 3 Phase, 460-480VAC, NEMA 4/12 Enclosure with AC-3 Bypass with Circuit Breaker & Keypad on Door
$2,937.56$2,937.56 -
Available Now! Available Now!Weg
SSW050023T2246TPZ
Soft Starter, Compact, 3 Phase, 7.5hp, 23 Amps, 208-480V, Variable Torque, Built In Bypass, Please Note The Suffix Update From EPZ to TPZ Was Only Due to A New Manual Included
$423.34$423.34 -
Weg
SSW050030T2246TPZ
Soft Starter, Compact, 3 Phase, 10hp, 30 Amps, 208-480V, Variable Torque, Built In Bypass, Please Note The Suffix Update From EPZ to TPZ Was Only Due to A New Manual Included
$459.94$459.94 -
Available Now! Available Now!Weg
SSW070312T5SH1Z
Soft Starter, 312A: 125hp/230VAC, 250hp/460VAC, 300hp/575VAC, Three Phase, 13.0 x 9.0 x 9.6" Frame Size 4, IP00, Built-In Internal AC-1 Bypass, Series SSW07
$3,045.12$3,045.12 -
Weg
SSW900D0365T5E3B
Soft Starter, 3 Phase, 365 Amp, 230/460/575VAC, 150/300/350hp, Frame D: 13.0H x 8.9W x 11.1D”, Protected Chassis Enclosure, IP00. (Please review and verify specifications for your application.)
$5,407.02$5,407.02 -
Weg
APS9-1-10HD
Soft Starter, 460VAC, ND|HD: 5hp, 10 FLA (Normal Duty: 350% FLA for 30s, 1.0 SF) | 5hp, 10 FLA (Heavy Duty: 450% FLA for 30s, 1.15 SF), AC3 Bypass, UL 3R, 4, 12 Wall Mount Enclosure 1, 32 x 20 x 16" (HWD), APS Series to Replace TPH Series
$7,003.75$7,003.75 -
Weg
APS9-1-125HD
Soft Starter, 460VAC, ND|HD: 125hp, 161 FLA (Normal Duty: 350% FLA for 30s, 1.0 SF) | 100hp, 125 FLA (Heavy Duty: 450% FLA for 30s, 1.15 SF), AC3 Bypass, UL 3R, 4, 12 Wall Mount Encl. 1, 32 x 20 x 16" (HWD), APS Series to Replace TPH Series
$9,262.50$9,262.50 -
Weg
APS9-1-19HD
Soft Starter, 460VAC, ND|HD: 15hp, 22 FLA (Normal Duty: 350% FLA for 30s, 1.0 SF) | 10hp, 19 FLA (Heavy Duty: 450% FLA for 30s, 1.15 SF), AC3 Bypass, UL 3R, 4, 12 Wall Mount Enclosure 1, 32 x 20 x 16" (HWD), APS Series to Replace TPH Series
$7,117.50$7,117.50 -
Weg
APS9-1-31HD
Soft Starter, 460VAC, ND|HD: 30hp, 40 FLA (Normal Duty: 350% FLA for 30s, 1.0 SF) | 20hp, 31 FLA (Heavy Duty: 450% FLA for 30s, 1.15 SF), AC3 Bypass, UL 3R, 4, 12 Wall Mount Enclosure 1, 32 x 20 x 16" (HWD), APS Series to Replace TPH Series
$7,361.25$7,361.25 -
Weg
APS9-1-43HD
Soft Starter, 460VAC, ND|HD: 40hp, 55 FLA (Normal Duty: 350% FLA for 30s, 1.0 SF) | 30hp, 43 FLA (Heavy Duty: 450% FLA for 30s, 1.15 SF), AC3 Bypass, UL 3R, 4, 12 Wall Mount Enclosure 1, 32 x 20 x 16" (HWD), APS Series to Replace TPH Series
$7,471.75$7,471.75
Soft starters are used to gradually increase the voltage and current when starting a motor. This helps limit the inrush current which reduces stress on the motor, the system and mechanical components.