Available Now! Available Now!Weg
CWM40-00-30V24
Contactor, IEC, 40 Amps, 208-240VAC, 3-Pole, UL508, Use RW Overload Relay
$70.52$70.52 -
Available Now! Available Now!Weg
ESW-B9V24A-R28
Enclosed Starter, 2hp@230V, 9A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 5.6-8A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination
$113.40$113.40 -
Weg
ESWF-9V18N4-D09
Combination Motor Starter, 1.5hp/200V, 1.5hp/230V, 3hp/460V, 5hp/575V, 120VAC Coil Voltage, 4.0-6.3A O/L Range, Wall Mount, Type 4/12 Metal Enclosure, HOA-Start/Stop/Reset, Circuit Breaker Rotary Handle Disconnect, FVNR
$803.70$803.70 -
Available Now! Available Now!Noark
EX9CDS12A30G7A
Contactor, IEC, 12A, 3NO+1NO Aux Contact, 120V, NC1-1210, 50/60HZ
$20.40$20.40 -
Available Now! Available Now!Noark
EX9CK30B20G7
DP (Definite Purpose) Contactor, Lug Terminals, 30 Amp (30A), 2NO, 120VAC, 50/60Hz, Ex9CK Series
$13.77$13.77 -
LS Electric
0705101500
Manual Motor Starter, 26A, (18-26A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705004700, 705004700, MMS-32S 26A EXP)
$52.60$52.60 -
Available Now! Available Now!Weg
CWM18-10-30V24
Contactor, IEC, 18 Amps, 1NO, 208-240VAC, 3-Pole, UL508, Use RW Overload Relay
$44.29$44.29 -
Noark
EX9RD25A10
Overload Relay, Use with 9/12/18/25A Std, 7-10A, NR2-25G 7-10A, Use with EX9CDS/EX9CDR Contactors
$24.79$24.79 -
Available Now! $28.00$28.00 -
Available Now! Available Now!Weg
RW67-1D3-U040
Overload Relay, 3 Pole, 25-40A, Class 10, 2.87 x 1.97 x 4.17" (HWD), Use with CWM32 to CWM40 Contactor Models
$48.72$48.72 -
LS Electric
0705100900
Manual Motor Starter, 6A, (4-6A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705004100, 705004100, MMS-32S 6A EXP)
$50.88$50.88 -
Available Now! Available Now!LS Electric
1298001400
Overload Relay, MT-32 15A 3K, Class 10, Screw Terminals, Only Use with MC-9B, MC-12B, MC-18B, MC-32B, and MC-40B Series Contactors
$43.17$43.17
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors