Weg
RW117-3D3-U080
Overload Relay, 3 Pole, 63-80A, Class 10, 3.94 x 2.95 x 3.89" (HWD), Use with CWB95 to CWB125 Contactor Models
$109.20$109.20 -
Weg
PESWS-B40D15EX-RM70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Reset Only, 25-40A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6" (HWD)
$221.40$221.40 -
Available Now! $14.45$14.45 -
Weg
PESW-B40D15EX-R70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Reset Only, 25-40A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6" (HWD)
$289.44$289.44 -
Weg
CWB95-11-30D02
Contactor, IEC, 95 Amp (95A), 3NO, 24VDC, 50/60Hz, Screw Terminal, 5.85 x 2.83 x 5.69" (HWD)
$142.35$142.35 -
Weg
PESWS-B38V24AX-RM69
Enclosed Starter, 38 Amp (38A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 25-40A O/L Range, Single Phase, NEMA 4X, Non-Metallic, Non Reversing Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0"(HWD)
$162.00$162.00 -
Weg
ESW-B40D15A-R70
Enclosed Starter, 10hp@230V, 40A (CWB40), 120V, 50/60Hz Coil Voltage, Start/Stop+Reset, 25-40A (RW67) O/L Range, 3 Phase, Metallic Encl., NEMA 1, Box M06 Dimensions: 13 x 7.5 x 5.6" (HWD), FVNR Non-Combination Across the Line Starter
$207.90$207.90 -
Weg
PESWS-B38D15AX-RM69
Enclosed Starter, 38 Amp (38A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 25-40A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)
$147.96$147.96 -
Weg
PESW-B32D45EX-R68
Enclosed Starter, 32 Amp (32A) CWB Contactor, 600V Coil Voltage, Reset Only, 22-32A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6" (HWD)
$141.48$141.48 -
Available Now! Available Now!Weg
ESW-B65D15A-R72
Enclosed Starter, 120V, 50/60Hz Control Voltage, 65A (CWB65), 40-57 A (RW67) Overload Relay, A-On-Off Button, Direct Three Phase, Metallic Crate, Type 1
$227.00$227.00 -
Weg
PESW-B18D45EX-R66
Enclosed Starter, 18 Amp (18A) CWB Contactor, 600V Coil Voltage, Reset Only, 11-17A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)
$101.52$101.52
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors