Available Now! Available Now!Noark
EX9CK40B20B7
DP (Definite Purpose) Contactor, Lug Terminals, 40 Amp (40A), 2NO, 24VAC, 50/60 Hz, Ex9CK Series
$18.79$18.79 -
LS Electric
0707100700
Manual Motor Starter, 63A, (45-63A), NCNR, This is the Latest Version of (0707000700, 707000700, MMS-100S 63A EXP)
$244.29$244.29 -
$127.89$127.89
-
Weg
RWM840E-3-A4U840
Overload Relay, 170-840A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 1000V for Contactor Model CWM
$728.00$728.00 -
Weg
RWM420E-3-A4U420
Overload Relay, 85-420A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 1000V for Contactor Model CWM
$324.80$324.80 -
Weg
RWM420E-3-A4U250
Overload Relay, 50-250A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$274.40$274.40 -
Weg
RWM40E-3-A4U040
Overload Relay, 8-40A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$81.20$81.20 -
Weg
RWM40E-3-A4U025
Overload Relay, 5-25A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$51.52$51.52 -
Weg
RWM40E-3-A4U008
Overload Relay, 1.6-8A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$51.52$51.52 -
Weg
RWM40E-3-A4U002
Overload Relay, Solid State, 3 Pole, 0.4-2A, Adjustable 10, 20, 30 Trip Class, Local Reset Only, 16 Max Fuse (gL/gG) A, Ui = 690V Maximum Insulation Voltage, Direct Mounting on CWM9 to CWM40 Contactor Models
$51.52$51.52 -
Weg
RWM112E-3-A4U112
Overload Relay, 28-112A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$134.40$134.40 -
Available Now! Available Now!Weg
RW67-5D3-U080
Overload Relay, 3 Pole, 63-80A, Class 10, 2.87 x 1.97 x 4.17" (HWD), Use with CWM40 to CWM80 Contactor Models
$62.72$62.72
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors