Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • Available Now!
    PESW-B32V24AX-R68
    Available Now!

    Weg

    PESW-B32V24AX-R68

    Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 208-240V Coil, Start / Stop+Reset, 4X, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    PESWS-B32V24AX-RM68
    Available Now!

    Weg

    PESWS-B32V24AX-RM68

    Enclosed Starter, 2hp@115V / 5hp@230V, 25A, 208-240V Coil, Start / Stop+Reset, 22-32A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    ESW-B25V24A-R33
    Available Now!

    Weg

    ESW-B25V24A-R33

    Enclosed Starter, 7.5hp@230V, 25A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 15-23A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • PESWS-B50V24AX-RM71

    Weg

    PESWS-B50V24AX-RM71

    Enclosed Starter, 50 Amp (50A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 32-50A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)

  • ESW-B9V24A-R29

    Weg

    ESW-B9V24A-R29

    Enclosed Starter, 3hp@230V, 9A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 7-10A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • ESW-B9V24E-R27

    Weg

    ESW-B9V24E-R27

    Enclosed Starter, 1.5hp@230V, 9 Amp (9A), 208-240V Coil, Reset Only, 4-6.3A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • ESW-B9V24E-R29

    Weg

    ESW-B9V24E-R29

    Enclosed Starter, 3hp@230V, 9 Amp (9A), 208-240V Coil, Reset Only, 7-10A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • ESWE-B18V24KX-D11

    Weg

    ESWE-B18V24KX-D11

    Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 208-240VAC Coil Voltage without CPT, 60Hz, 10 - 16 Amp MPW40 Overload Relay

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors