Weg
PESW-B25V24EX-R67
Enclosed Starter, 7.5hp@230V / 15hp@460V, 25A, 208-240V Coil, Reset Only, 15-23A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$111.20$111.20 -
Weg
PESW-B32D15AX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 120V Coil, Start / Stop + Reset, 4X, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$148.60$148.60 -
Weg
PESW-B9D39EX-R61
Enclosed Starter, 1.5hp@230V / 3hp@460V / 5hp@575V, 9A, 480V Coil, Reset Only, 4-6.3A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$78.29$78.29 -
Weg
PESW-B9D39EX-R62
Enclosed Starter, 2hp@230V / 5hp@460V, 9A, 480V Coil, Reset Only, 5.6-8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$78.29$78.29 -
Weg
PESWS-B18V24AX-RM66
Enclosed Starter, 1hp@115V / 3hp@230V, 18A, 208-240V Coil, Start / Stop+Reset, 11-17A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$90.76$90.76 -
Weg
PESWS-B40D15AX-RM70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 25-40A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$208.44$208.44 -
Weg
ESWE-B18D15KX-D11
Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 10 - 16 Amp MPW40 Overload Relay
$498.75$498.75 -
Weg
ESWE-B18D39KX-D11
Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 10 - 16 Amp MPW40 Overload Relay
$498.75$498.75 -
Weg
ESWE-B25D15KX-D12
Enclosed Starter for 7-1/2hp@200V, 7-1/2hp@230V, 15hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 25 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 16 - 20 Amp MPW40 Overload Relay
$513.00$513.00 -
Weg
ESWE-B25D39KX-D12
Enclosed Starter for 7-1/2hp@200V, 7-1/2hp@230V, 15hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 25 Amp CWB Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 16 - 20 Amp MPW40 Overload Relay
$513.00$513.00 -
Weg
ESWE-B38D39KX-D14
Enclosed Starter for 10hp@200V, 10hp@230V, 20hp@460V, 25hp@575V Maximum hp 3-Phase Motor, 38 Amp CWB38 Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 25 - 32 Amp MPW40 Overload Relay
$564.30$564.30 -
Weg
ESWE-B40V24KX-D14
Enclosed Starter for 10hp@200V, 10hp@230V, 20hp@460V, 25hp@575V Maximum hp 3-Phase Motor 40 Amp CWB38 Contactor, 208-240VAC Coil Voltage without CPT, 60Hz, 25 - 32 Amp MPW40 Overload Relay
$534.60$534.60
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors