GSR05RSPN-N
Alt: Middle-G Series
$92.66
Photoelectric Sensor, Diffuse Reflective, PNP, Red LED, 500mm Range, 12/24VDC, M8 Connector, IP67
- Weight:
- 0.25 LBS
- Minimum Purchase:
- 1 unit
Description
Photoelectric Sensor, Diffuse Reflective, PNP, Red LED, 500mm Range, 12/24VDC, M8 Connector
Features Include:
- Completely filled with resin to be IP67 compliant
- Improved water resistance and intensity suitable for conveyor lines
- The operation mode can be selected by a switch
- Sensitivity adjustment for fine detection
- Globally compatible PNP types also conveniently provided with stability output
- Optional rigid protective cover (mounting bracket) available
- Detection Method: Diffuse reflective type
- Detection Distance: 500mm (100 x 100mm white drawing paper)
- Detection Object: Opaque, translucent, and transparent
- Power Supply: 12 - 24V DC ±10% / Ripple 10% or less (* 5VDC model)
- Current consumption: 35mA or less
- Operation Mode: Light-ON / Dark-ON selectable (with switch)
- Response Time: 0.5ms or less
- Hysteresis: 10% or less
- Light source (light wavelength): Red LED (700nm)
- Volume (VR): SENS: Sensitivity adjustment (on receiver for through-beam type)
- Switch (SW): Light-ON / Dark-ON selector switch
- Material: Case: Polyarylate, Lens: Acrylic
- Weight: approx. 80g
Output Mode:
- Control output: PNP open collector output Rating: source current 100mA (30 VDC) or less
- Residual voltage: 2 V or less
- Stability output: NPN open collector output Rating: sink current 50mA (30 VDC) or less
- Residual voltage: 1 V or less
Connection:
- Attached cable (outer diameter 4.2)
- Transmitter: Transmitter of through-beam type: 0.3 mm2 2 core 2 m length (gray)
- Receiver of through-beam type, reflective type : 0.2 mm2 4 core 2 m (black)
Indicator:
- Red LED: Operation indicator
- Green LED: Stability Indicator
Environmental Specifications:
- Ambient Light: 5,000 lx or more
- Ambient Temperature:-25 - +55C (non-freezing)
- Ambient Humidity: 35 - 85%RH (non-condensing)
- Vibration: 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction
- Shock: 500 m/s2 / 3 times each in 3 directions
- Dielectric withstanding: 1,000 VAC for 1 minute
- Insulation resistance: 500 VDC, 20 MΩ or higher