The world’s only self powered infrared thermocouple. Pre-calibrated IRt/c's are best for low temperatures (< 500 °F) and non-metal or coated metal surfaces.
No active electronics, so these passive devices can not fail.
Mean Time Between Failure reports have been documented with a rate of >1,000 years between failures. The patented technology separates the IRt/c from all other non -contact temperature products. Our Exergen sensors will minimize downtime and increase your production.
The IRt/c family of pre-calibrated IRt/c's includes:
- Series (Short ID# begin with)
- IRt/c.01 (1141)
- IRt/c.03 (1142)
- IRt/c.07 (138)
- IRt/c.10 (115)
- IRt/c.1X (110/111)
- IRt/c.2 (117/118/119)
- IRt/c.3SV (130)
- IRt/c.3x (1185/1194)
- IRt/c.5 (120/121/122)
- IRt/c.SV (112/113/114)
- IRt/c- (109/110/111)
- microIRt/c (uIRt/c #'s - 150)
Learn even more about Exergen Sensors here!
Features Include:
- Sensing Range: -50 to 1200 °F (-45 to 650 °C)
- Field-of-View: 10:1 (6°) approximately
- Minimum Spot Size: 0.8" (20 mm)
- Spectral Response: 6.5 to 14 µ
- Output Impedance: 4 to 8 Kohms approximately
- Cable: Twisted shielded pair of base thermocouple material (J, K, etc.), 3 ft. (.9) m) standard length, Teflon sheathed, rated to 392 ºF (200 ºC) continuous service.
- Dimensions: 3.76" x 1.375" Diameter (96 x 35 mm)
- Weight: 6.5 oz (184 g) with cable
- Housing: Stainless steel, hermetically sealed, exceeds NEMA 4, 4x; IP65, 67, intrinsically safe, cable shield grounded to housing and electrically isolated from signal.
Air Purge
- Built-in; cooling capacity to 400 °F (200 °C) ambient; 3', (0.9 m) polyurethane tubing provided.
- Air purge pressure: 5 psig - 20 psig (for 400 °F (200 °C) ambient).