The Euchner CET series is used to guard lock for perseonnel protection in accordance with EN 14119.
This series offers very high guard locking of up to 6500N, 2 safety outputs, a head that can be rotated in 90° steps and it is IP67 rated. The metal housing and safety category 4 and PL e according to EN ISO 13849-1 make this the right safety switch for you!
CET-AP - Single device
- Safety switch with guard locking and safe guard lock monitoring
- Integrated CES-AP electronics
- No special evaluation unit required
- Safety category 4 and PL e in accordance with EN ISO 13849-1 with any mounting position, head down/up/horizontal
- Two safe semiconductor outputs and signal output OUT
- Safety outputs with clocking
- Input (optional) for connection of feedback loop and start button
CET-AR - For connection of up to 20 AR devices
- Safety switch with guard locking and safe guard lock monitoring
- Integrated CES-AR electronics
- No special evaluation unit required
- Series connection of up to 20 devices (CES-AR, CET-AR, MGB-AR, ...) in an AR chain possible
- Safety category 4 and PL e according to EN ISO 13849-1 with any mounting position, head down/top/level
- Two safe semiconductor outputs and signal output OUT
- Safety outputs with clocking
- Input (optional) for connection of feedback loop and start button
CET-AS - For direct connection to AS-Interface
- ntegrated AS-i connection
- Robust metal housing
- Suitable for heavy doors
- High tamper resistance
- High protection class IP67
- Detailed diagnosis with four LEDs (ASi/STATE, 2 colors each)
Features Include:
- Guard locking with guard lock monitoring
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
- With lens set, 6 pcs.
- incl. adhesive labels
- With cable entry
- Unicode
- Housing material: Housing Reinforced plastic; die-cast zinc nickel-plated, stainless steel
- Ambient temperature: At UB = 24V DC -20 - 55 °C
- Degree of protection: IP65
- Mechanical life: 1 x 106, In case of use as door stop, and 1 Joule impact energy 0,1 x 106
- Installation orientation: Door hinge DIN right
- Switching frequency: 0.25 Hz
- Connection Cable entries: M20x1.5
- Guard locking principle: Closed-circuit current principle
- Locking force FZh: 2000 N
- Utilization category acc. to EN 60947-5-2: DC-13 24V 200mA
- Rated insulation voltage: Ui 30 V
- Rated impulse withstand voltage Uimp: 1.5 kV
- Degree of contamination (external, according to EN 60947-1): 3
- Connection cross-section: (Rigid/flexible) 0.13 - 1,5 mm², (Rigid/flexible) with cable end sleeve according to DIN 46 228/1 0,25 - 1,5 mm², (Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0,25 - 0,75 mm²
- Discrepancy time Between FO1A and FO1B: max.10 ms